Click 112/114 Contact Closure
INSTALLER QUICK-REFERENCE GUIDE
www.wavetronix.com
801.734.7200
2
Understand the device’s configuration features
e following physical features allow you to congure the Click 112/114:
˽ Mode Switch – Allows you to cycle through and select menu and congura-
tion options.
˽ Level 1 LEDs – Light up to indicate menu options while cycling through the
menu. ey also have the following functions:
˿ Red – Lights up when the device has power
˿ Blue – Currently has no function
˿ Green – Lights up when the device is transmitting data
˿ Yellow – Lights up when the device is receiving data
˽ Level 2 LEDs – Light up to indicate conguration options. When the de-
vice is not in menu mode, these LEDs are o.
˽ Channel LEDs – e topmost bank of LEDs. ese light up to indicate
vehicle detection.
˽ DIP Switches – Located on the lower part of the circuit board (le face of the board, if you’re looking at
the faceplate). ese switches allow you to congure the device. is will be covered in greater detail in
Part 4.
www.wavetronix.com
801.734.7200
1
Mount and connect the device
Use the following steps to install the Click 112/114 rack cards:
1 If youre using hardware conguration, set all DIP switches before
installing Click 112/114 devices (this will be covered in Part 4 of
this document).
2 Insert the cards into the rack.
3 Daisy-chain together all the cards in your installation, using short
RJ-11 jumper cables.
4 Connect the rst Click 112/114 card to the SmartSensor via a Click
200 or Click 222 surge protector and a 60” RJ-11 patch cord.
Note. Bus 1 should be used to connect to the sensor, and bus 2 for conguration.
Channel
1 2 3 4
Menu
PWR PU TD RD
Level 1
Mode Switch
Level 2
1 2 3 4
Vista de pagina 0
1 2 3 4

Indice de contenidos

Pagina 1 - Click 112/114 Contact Closure

Click 112/114 Contact ClosureINSTALLER QUICK-REFERENCE GUIDEwww.wavetronix.com 801.734.72002 Understand the device’s configuration featurese followin

Pagina 2 - Select configuration method

3 Select configuration method4 Configuration option 1: DIP switchese DIP switches on the circuit board can be used to change input mapping and the baud

Pagina 3 - Reset to Default

5 Configuration option 2: front panel menue front panel menu allows you to congure input mapping and baud rates. It can also reset the device to fact

Pagina 4 - Select a driver

WX-500-017 7© 2014 Wavetronix LLC. All rights reserved. Protected by US Pat. Nos. 6,556,916; 6,693,557; 7,426,450; 7,427,930; 7,573,400; 7,889,097; 7,

Comentarios a estos manuales

Sin comentarios