SmartSensor 105
INSTALLER QUICK-REFERENCE GUIDE
2
Select the mounting height
1 Determine the oset by
measuring the distance
from the nearest detec-
tion lane to the pole the
sensor is mounted on.
2 Find the recommended
mounting height by us-
ing this table.
e range of ideal osets is
highlighted in gray.
www.wavetronix.com
801.734.7200
1
Identify the components in your system package
Complete steps 1–9 to integrate the Wavetronix SmartSensor into your trac application. If
you need technical support or have questions, please contact Wavetronix Technical Services at
801.734.7200. For more information, see the SmartSensor User Guide.
e components below are common for a SmartSensor 105 installation; the contents of your package may
be dierent.
Sensor
Mounts
Sensors Sensor
Cables
Pole
Cabinets
Homerun
Cable
Installation
CD
Mount Bracket Sensor Sensor
Cable
Homerun
Cable
Pole
Cabinet
Oset from first
detection lane
(ft/m)
Recommended
mounting height
(ft/m)
Minimum
mounting height
(ft/m)
Maximum
mounting height
(ft/m)
10/3 12/3.7 9/2.7 15/4.6
15/4.6 15/4.6 12/3.7 18/5.5
20/6.1 18/5.5 15/4.6 20/6.1
25/ 7. 7 20/6.1 17/5.2 25/ 7.7
30/9.1 22/6.7 19/5.8 30/9.1
35/10.7 23/ 7. 0 20/6.1 35/10.7
40/12.2 25/ 7. 7 22/6.7 40/12.2
45/13.7 27/8.2 23/ 7. 0 45/13.7
50/15.2 30/9.1 25/ 7. 7 must be < oset