76 CHAPTER 7 LANES & STOP BARS
Figure 7.11 – Zoom In Feature
After you click on Adjust Bins or Adjust All, the Sensitivity Slider window will appear
(see Figure 7.12). Click on the up/down buttons to change the sensitivity (in decibels).
Negative values will lower the rejection threshold in order to increase sensitivity; positive
values will increase the rejection threshold in order to decrease sensitivity.
Figure 7.12 – Sensitivity Slider Window
Automatic Configuration
Use the following steps to auto-congure the SmartSensor Matrix:
1 Move the sensor to the appropriate location by clicking the button.
2 Click the button to clear the edit area.
3 If necessary, restart Automatic Lane Conguration by clicking the button and
selecting Restart Auto Lane Cfg from the window. Allow the intersection to cycle at
least twice before proceeding (this will take approximately 5 to 10 minutes).
4 Capture lanes & stop bars to edit area.
5 Make any necessary manual adjustments.
6 Save the desired changes to the sensor.
Note
Lanes have a direction shown by white arrows on top of the lane. To switch the
lane direction, simply click on the arrows. (To be able to change lane direction, there
must not be any display overlays on.) Before you save the configuration, make sure
that all the arrows are pointing in the correct direction.