APPENDIX CLICK 340/341/342 MANAGED SWITCHES 73
Maximum overrange multi-mode -14 dBm
Minimum transmission length, including 3 dB
system reserve, when using single-mode
36 km glass fiber with F-G 9/125 0,36 dB/km
32 km glass fiber with F-G 9/125 0,4 dB/km
26 km glass fiber with F-G 9/125 0,5 dB/km
Maximum transmission power single-mode -8 dBm
Minimum transmission power single-mode -15 dBm
Minimum recierver sensitivity single-mode -31 dBm
Maximum overrange single-mode -7 dBm
Transmission speed 100 MBps
RS-232 (V.24) communication interface
Number 1
Connection format Mini-DIN female connector on the switch
Floating alarm contact
Voltage 24 V DC
Current carriyng capacity 100 mA, maximum
Table A.2 – Interfaces
Mechanical Tests
Shock test according to IEC 60068-2-27 Operation: 25g, 11 ms period, half-sine shock
pulse Storage/transport: 50g, 11 ms period,
half-sine shock pulse
Vibration resistance according to IEC 60068-
2-6
Operation/storage/transport: 5g, 150 Hz,
criterion 3
Free fall according to IEC 60068-2-32 1 m
Table A.3 – Mechanical Tests
Conformance With EMC Directives
Developed according to IEC 61000-6.2
Noise emission according to EN55022: 1998 +
A1: 2000 + A2: 2003 (interference voltage)
Class A (industrial applications)
Noise emission according to EN55011: 1998 +
A1: 1999 + A2: 2002 (electromagnetic interfer-
ence)
Class A (industrial applications)
Noise immunity according to EN61000-4-2
(IEC1000-4-2) (ESD)
Contact discharge:
Air discharge:
Indirect discharge: Requirements according to DIN EN 61000-6-2
Test intensity 2, criterion B