CHAPTER 11 TOOLS 121
Restoring the Configuration
Click the Restore Sensor Setup button to load a conguration and overwrite the current
conguration. e Select Settings to restore screen allows you to specify which types of
conguration data will be restored (see Figure 11.4). Make changes by checking or un-
checking specic settings.
Figure 11.4 – Restore Settings
Conguration categories that are not dened in the restore le are grayed out and may not
be selected for restoration. Click OK to perform the backup process and save the new set-
tings to FLASH. Click Cancel to return to the Backup/Restore screen.
Note
If the serial baud rate being restored is dierent than the baud rate being used for
the current connection, you will be prompted to accept the new baud rate or keep the
existing baud rate.
If an error occurs, the conguration le may be invalid and the message shown in Figure
11.5 will be displayed. Clicking Yes will reboot the sensor and reload the last conguration
that was saved to FLASH; click No to try again.
Figure 11.5 – Restore Configuration Error