CHAPTER 4 SENSOR TOOLBAR 35
2 Enter the IP/Hostname of the sensor or communication server and the Port number
through which Collector will communicate. Ranges can be used to add more than one
sensor at the same time (see Figure 4.3).
Figure 4.3 – Add Sensor Info Fields
Depending on the sensor and communication setup, a multi-drop ID or a unit address
may be required. e Multi-drop ID eld will not be displayed if it is not necessary for
the selected driver. In other cases, the Multi-drop ID eld will be visible and relabeled
with a new name to correspond to the particular address or eld name used by the
device for user clarity.
e Custom ID eld is optional and can be used to enter any additional identication
information.
3 Enter the initial collection interval (in seconds) into the Collection Interval eld. For
sensor drivers that support automatic querying of the sensor interval, the Use Sensor
Interval option will be displayed. Check this box to use the sensor interval as the col-
lection interval.
4 Select the time zone that the sensor resides in from the Time Zone drop-down list and
mark whether the sensor location observes daylight savings time. is will allow Col-
lector to adjust sensor time to local time for proper timekeeping and data storage (see
Figure 4.4).
Figure 4.4 – Additional Add Sensor Fields
e Start Collecting Data Immediately option determines whether data collection is
started or stopped for the new sensor once it is added. If the communication pathway
to the sensor is open, data collection can begin immediately; if the Start Collecting
Data Immediately option is checked, Collector will attempt to retrieve the sensor’s
conguration aer it is added to the system. However, if the sensor is not connected
and congured properly, it is recommended that this option be turned o. If the op-
tion is not turned o, Collector will continue to attempt to connect and will simply log
errors aer every collection interval.
e Attach to Multi-drop Server (if available) option is used when multiple sensors
share a common IP address and port. is option will only be available if the selected