60 CHAPTER 5 SENSOR CONFIGURATION PAGE
Figure 5.10 – Approaches
To add lanes to an approach, hold the mouse button down anywhere on the lane row and
drag the row onto the name of the desired approach. Lanes are listed in the approach display
and sorted by lane ID for convenience. ere is no limit to how many lanes can be assigned
to the same approach. Approaches without lane assignments can be kept as part of the sen-
sor conguration and will have no eect on Collector operation.
To edit an existing approach, select the approach name in the list on the le, change the
name, type or direction as desired and click Update Approach.
To delete an approach, select the approach in the list and click the Delete Approach but-
ton. All lanes assigned to a deleted approach will automatically be reassigned to the rst
approach in the list. e last remaining approach for a sensor cannot be deleted. Deleting
an approach has no eect on data collection or sensor conguration.
Saving Changes
All changes made to Lane/Approach conguration, including custom IDs, are not perma-
nently saved unless you click the Save Changes button. Click Cancel Changes to abandon
any recent changes and return to the previously saved Lane/Approach conguration. A
warning will appear if you attempt to switch tabs or navigate to another page with unsaved
changes.
Sensor Commands Tab
e Sensor Commands tab allows you to send specic commands directly to the sensor
(see Figure 5.11). To send a command, select the radio button next to the command name
and click the Run Command button. e result will be displayed in the Result eld at the
bottom of the screen. If a driver does not support a command, the command option will
be grayed out.