Wavetronix SmartSensor 105 (SS-105) - User Guide Manual de usuario Pagina 67

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 99
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 66
66 CHAPTER 6 LANE SETUP
To do this, click on the Edit Lane Name button and the Edit Lane Names window will
appear. Highlight the current lane name by double-clicking on it, then type in the lane’s
new alphanumeric identication of up to eight characters.
To reorder the lanes, you will rst need to enter a “#” sign and then the lane number. Once
you enter “#1,” for example, you can add NB” or any other name with the remaining char-
acters.
Note
The RTMS protocol can report up to eight lanes. By default, the first zone is asso-
ciated with the lane closest to the sensor; the second zone is associated with the
next closest lane and so on. .To map the lanes in a dierent order, enter the “#”
sign followed by a unique number character between 1 and 8. (Unused lanes do not
need to be named.) The other characters are ignored but may be used for clarification
purposes. Remember, a lane with the name “#1” will be reported first in the RTMS
protocol, corresponding to zone 1; a lane with the name “#2” will be reported second,
corresponding to zone 2.
Lane names can also be changed by going to Sensor Settings and clicking on the Data
Collection tab (see chapter 7 for more information).
Saving the Configuration
Once all congurations are completed, the changes must be updated in the SmartSensor’s
ash memory (lane changes wont take eect until after the sensor has been updated). Up-
date all manual changes by clicking the Update button located below the manual tool but-
tons (see Figure 6.6). e process of updating the conguration takes only seconds. Once
the process is completed, SmartSensor Manager will remain on the Lane Conguration
page so that any manual changes made may be viewed and easily changed if needed.
Figure 6.6 – Update, Undo, and Restart Buttons
Undoing Manual Changes
Unsaved changes may be undone without repeating the manual conguration process.
Click on the Undo button found below the manual tool buttons (see Figure 6.6). is
tool retrieves the last saved conguration from the SmartSensor, eectively undoing any
unsaved changes that were made.