76 CHAPTER 7 DATA COLLECTION
e sensor’s SRAM buer contains up to 246 of the most recent interval data records.
is type of storage is temporary because SRAM is volatile—its contents will be lost if the
sensor’s power supply is interrupted. e sensor’s ash memory buer contains up to 2975
interval data records. is type of storage is permament because ash memory is nonvola-
tile—it will retain its contents even if the sensor’s power supply is interrupted.
Note
The smallest amount of flash memory that can be erased at one time represents
several interval data records. As a result, if you are collecting data with the Memory
Ovewrite feature enabled, you will not typically see the buer fill up 100%. In fact,
you may see the usage fall from near 100% to something near 80%. This is because
as usage approaches 100%, a portion of the oldest contents are erased in order to
make room for newer data.
If you want to force the contents of the sensors SRAM buer to be written to ash mem-
ory, click the Transfer>> button.
Data Download
To download interval data stored on the sensor in the SRAM and ash memory buers—
such as data collected in a study—go to Data Collection > Download. e screen that
comes up is divided into two sections, Download Interval Data and Interval Data Buers
(see Figure 7.3).