CHAPTER 7 DATA COLLECTION 77
Download Interval Data
Under the Download Interval Data section, click the Browse button. is will open a di-
rectory box where you can either create a new data download le log or locate an existing
download le log. Once you’ve selected an existing le or entered the name of the new le,
select Open.
Next, select the type of download to perform. e following types of download sessions are
available:
Normal – Retrieves all interval data from the beginning of the study to the most recent
record. e number of lanes per record is determined by the number of lanes currently
congured on the sensor.
Incremental – Retrieves only the interval data that was recorded after the indicated
date and time. e number of lanes per record is determined by the number of lanes
currently congured on the sensor.
Error Recovery – Retrieves the entire contents of the ash memory buer. e ash
memory buer contains 2976 records and each record has data for eight lanes. e
contents of SRAM are not retrieved in this mode. You can perform this type of down-
load to verify the contents of the ash memory buer in the event that a normal or
incremental download does not retrieve all the data that you expect to receive.
Once you have selected the type of download, click Download.
Note
Each time a data download is performed, a header is inserted into the log file that
indicates the date of the download.
Data in the SRAM buer contains the most recent information and will be downloaded
rst. If there is any data in the ash buer, it will be downloaded second. However, before
the data is written to the log le it will be reordered, so that the oldest data intervals will
be near the top of the le.
If you want to cancel the download or if you only want to download a certain number of
intervals, click the Stop button as soon as the desired number of interval data records are
downloaded. Once the download process has stopped, a window is displayed that indicates
number of interval data records that were downloaded.