74 CHAPTER 7 DATA COLLECTION
Figure 7.1 – Data Collection Setup
Step 1: Configure Data Storage
e Interval (Bin) Size option species the interval of time over which trac variables
like volume, speed, occupancy and classication are aggregated. is type of data is called
interval data. e minimum interval allowed is ve seconds.
By default, the checkbox next to Memory Overwrite is checked. is means that your
study will run indenitely and repeatedly overwrite the ash memory onboard storage.
is means that in order to not lose collected data, you must download it to a log on your
computer before it is overwritten.
Alternatively, you can uncheck the Memory Overwrite checkbox. In this case, the study
will run only until the sensors ash memory has been lled with interval data.
Note
Once the flash memory buer is full, it must be erased before it can be reused. Before
you erase the stored data, you will want to download the data to a log file on your
computer.
e third line under Step 1 displays the Flash Storage Time. is shows the duration of
interval data that a full ash buer holds, calculated for you as a number of days and hours.
Because of the way ash memory is managed, the Flash Storage Time will vary based on
whether or not you have Memory Overwrite enabled.